O-Level Physics Induction Practical: A Magnet, Coil and Galvanometer

Study guide
Chee Wei Jie
Reviewed by
Chee Wei Jie·Academic Advisor (Physics)

Observe induced current with a passive magnet-and-coil setup.

  • Compare movement, direction and poles, and understand what a galvanometer deflection can show.

A magnet held still inside a stationary coil gives a different observation from a magnet moving through it. Changing the magnetic flux linked with the coil induces an electromotive force. In a closed conducting circuit, the resulting current can deflect a galvanometer.

This supervised reference setup uses an ordinary supplied bar magnet, a coil and a trainer-approved centre-zero galvanometer. No external power supply is connected. Read the general lab safety guide before the apparatus briefing.

Know what the instrument measures

The 2026 O-Level Physics syllabus, 6091, includes electromagnetic-induction investigations on pages 31-32. The Institute of Physics magnet-and-coil activity illustrates the changing-flux and current distinction.

A galvanometer responds to current. Its needle movement is not a direct voltage reading or a calibrated measurement of emf unless additional suitable equipment and a defined method are supplied. Describe the observation as a deflection, its direction and its approximate size under the same arrangement.

Deflection direction depends on the connections and pole movement. Record which pole enters which end of the coil and how the meter leads are connected before labelling a direction. There is no universal rule that an entering north pole always makes every meter deflect left.

Check the passive circuit

Have the trainer check the meter, coil and prepared leads while the apparatus is stationary. Support the coil and make sure the supplied magnet fits through its clear opening without striking it. Route loose leads away from the moving magnet and keep fingers clear of possible trapping points.

Use only the assigned magnet. Substituting a stronger magnet changes both the magnetic behaviour and handling concerns. Do not connect a battery to make a weak induction observation larger; that would create a different circuit and a different investigation.

Compare controlled observations

  1. Record the lead arrangement and magnet orientation. Check the instrument's starting indication with everything stationary.
  2. Move the assigned pole gently into the coil through the briefed travel range. Record the deflection while it moves.
  3. Hold the magnet stationary and record the observation after motion has stopped.
  4. Withdraw it along the same path and compare deflection direction.
  5. Repeat with the other pole, keeping the connections fixed. Compare slower and faster approved movements qualitatively, without striking the coil.

Repeat a condition before changing another feature. A shifted coil, changed path or swapped lead can change the observation independently of the variable you meant to test. Stop for a chipped magnet, damaged lead, unstable coil or an instrument that behaves unexpectedly. Show the trainer before adjusting the setup.

Explain the pattern without overstating it

Entering and withdrawing a pole reverse the change in linked flux and normally reverse the deflection in the unchanged circuit. Reversing the pole also reverses the pattern. A stationary magnet and coil do not maintain a changing flux merely because the field is strong.

Faster hand movement can produce a larger observed deflection under the same setup. Hand motion is not a calibrated speed control, however, and the instrument has its own response time. Do not claim that doubling a hand movement speed doubled emf from two needle observations. Quantitative testing needs a measured motion and an appropriate electrical measurement method.

Return the equipment

Wait until the magnet and coil are stationary before disconnecting or repositioning. Return the magnet using its assigned storage arrangement, tidy leads and report damage before reuse. The electricity and magnetism practical manual provides the broader context for this passive investigation.