Pearson International A Level Physics Core Practical 13: Determine specific latent heat

Study guideUpdated 16 Oct 2026

Pearson IAL Physics practical notes on determine specific latent heat.

This outline relates measured energy to the mass undergoing a specified phase change. It supports development of a locally approved method and thermal/electrical risk assessment; it is not a complete validated procedure. Melting and boiling need different mass collection and background-transfer checks. Check current Pearson documents for course-specific requirements.

A Pearson Edexcel Physics practical map with four experiment-specific evidence checks

Aim and scientific principle

Determine the specific latent heat for a stated substance, phase change and pressure by relating net phase-change energy to the mass that actually changes phase. A nearly constant temperature supports the chosen transition model but does not prove that all supplied electrical energy causes that transition.

Begin by translating the title into a testable question. Identify what is deliberately changed, what is measured directly, what is calculated and what must remain controlled. Predict a relationship only after naming the mechanism. A prediction without a reason is weak; a reason without measurable variables cannot guide a practical design.

Apparatus and setup

Use a suitable low-voltage heater, phase-change sample, appropriate insulation, balance, voltmeter and ammeter or electrical energy meter, timer and temperature probe. For melting ice, collect and weigh drained meltwater rather than interpreting the mass of an entire closed ice/water container as melted mass. For boiling, use an appropriate vented arrangement and establish how vessel mass loss represents escaping vapour; splashes and condensate return can invalidate that identification. Consider measuring range, resolution, uncertainty, calibration and suitability for the sample, not the instrument name alone. Draw a labelled scientific setup that shows the working geometry and exactly where readings are taken. Include a control or blank when it distinguishes the target effect from drift, contamination or background response.

Before collecting results, check zero readings, calibration, leaks, alignment or sterility as relevant. Record the instrument resolution beside the first raw-data table. If a digital device displays more digits than its underlying accuracy supports, do not treat every digit as equally certain.

Method

  1. Choose melting or boiling and document the phase-changing mass measurement. Establish the relevant transition condition at the stated pressure before the measurement interval. Do not count initial warming of a cold sample or apparatus as latent heat; remove or quantify pre-existing liquid in a meltwater collection method.
  2. Measure voltage across and current through the heater over the same timed interval as the mass measurement. Record temperature and electrical variation. Ensure safe heater coverage and heat transfer under the approved setup; the electrical meter reading alone does not establish energy delivered to the changing phase.

Check this topic from memory

Attempt the matching topic bank before reopening the notes. Use each missed idea to decide what to review next.

Start the topic quiz